Product Introduction
The AC/DC solar submersible pump is a dual-mode water pump system compatible with both AC and DC power. It can operate directly using DC power from solar panels or batteries, or connect to a conventional AC power grid. Through an intelligent controller, it automatically identifies the power source and switches operating modes, prioritizing solar power when sunlight is sufficient, and seamlessly switching to the grid or backup power during cloudy or rainy days or at night, ensuring uninterrupted water supply.
4/6SSC-AC/DC Performance Data
|
No. |
Pump |
Controller |
Solar Panels |
|||||||
|
WASSERMANN CODE |
Ref.# |
R. flow (m³/h) |
Motor power (HP) |
Stages |
Drive Type |
Power(KW) |
AC Voltage Range (V) |
VOC Range (V) |
MPPT Voltage Range (V) |
|
|
431 |
4/6SSC17/1-A/D |
26m³/h-18m-150V-1100W |
17 |
1.5 |
1 |
AC/DC |
WAD solar 1.1kw |
80-280V |
80-430V |
150-350V |
|
432 |
4/6SSC17/2-A/D |
30m³/h-31m-180V-1500W |
17 |
2 |
2 |
AC/DC |
WAD solar 1.5kw |
80-280V |
80-430V |
180-350V |
|
433 |
4/6SSC17/3-A/D |
30m³/h-52m-280V-2200W |
17 |
3 |
3 |
AC/DC |
WAD solar 2.2kw |
80-280V |
80-430V |
280-350V |
|
434 |
4/6SSC17/4-A/D |
30m³/h-70m-300V-3000W |
17 |
4 |
4 |
AC/DC |
WAD solar 3kw |
80-280V |
80-430V |
300-350V |
|
435 |
4/6SSC30/2-A/D |
52m³/h-32m-280V-2200W |
30 |
3 |
2 |
AC/DC |
WAD solar 2.2kw |
80-280V |
80-430V |
280-350V |
|
436 |
4/6SSC30/3-A/D |
52m³/h-48m-300V-3000W |
30 |
4 |
3 |
AC/DC |
WAD solar 3kw |
80-280V |
80-430V |
300-350V |
|
437 |
4/6SSC15/5-A/D |
30m³/h-70m-530V-3000W |
15 |
4 |
5 |
AC/DC |
WAD solar 3kw |
260-480V |
200-900V |
480-650V |
|
438 |
4/6SSC18/5-A/D |
36m³/h-88m-530V-4000W |
18 |
5.5 |
5 |
AC/DC |
WAD solar 4kw |
260-480V |
200-900V |
480-650V |
|
439 |
4/6SSC18/6-A/D |
36m³/h-105m-530V-5500W |
18 |
7.5 |
6 |
AC/DC |
WAD solar 5.5kw |
260-480V |
200-900V |
480-650V |
|
440 |
4/6SSC18/7-A/D |
36m³/h-122m-530V-7500W |
18 |
10 |
7 |
AC/DC |
WAD solar 7.5kw |
260-480V |
200-900V |
480-650V |
|
441 |
4/6SSC17/7-A/D |
36m³/h-175m-530V-9200W |
17 |
12.5 |
7 |
AC/DC |
WAD solar 9.2kw |
260-480V |
200-900V |
480-650V |
|
442 |
4/6SSC18.5/7-A/D |
36m³/h-190m-530V-11000W |
18.5 |
15 |
7 |
AC/DC |
WAD solar 11kw |
260-480V |
200-900V |
480-650V |
|
443 |
4/6SSC31/4-A/D |
52m³/h-48m-530V-3000W |
31 |
4 |
4 |
AC/DC |
WAD solar 3kw |
260-480V |
200-900V |
480-650V |
|
444 |
4/6SSC30/4-A/D |
52m³/h-64m-530V-4000W |
30 |
5.5 |
4 |
AC/DC |
WAD solar 4kw |
260-480V |
200-900V |
480-650V |
|
445 |
4/6SSC30/5-A/D |
52m³/h-80m-530V-5500W |
30 |
7.5 |
5 |
AC/DC |
WAD solar 5.5kw |
260-480V |
200-900V |
480-650V |
|
446 |
4/6SSC30/6-A/D |
52m³/h-96m-530V-7500W |
30 |
10 |
6 |
AC/DC |
WAD solar 7.5kw |
260-480V |
200-900V |
480-650V |
|
447 |
4/6SSC30.1/6-A/D |
52m³/h-128m-530V-9200W |
30.1 |
12.5 |
6 |
AC/DC |
WAD solar 9.2kw |
260-480V |
200-900V |
480-650V |
|
448 |
4/6SSC30.2/6-A/D |
52m³/h-160m-530V-11000W |
30.2 |
15 |
6 |
AC/DC |
WAD solar 11kw |
260-480V |
200-900V |
480-650V |
|
449 |
4/6SSC35/2-A/D |
65m³/h-40m-530V-4000W |
35 |
5.5 |
2 |
AC/DC |
WAD solar 4kw |
260-480V |
200-900V |
480-650V |
|
450 |
4/6SSC35/3-A/D |
65m³/h-60m-530V-5500W |
35 |
7.5 |
3 |
AC/DC |
WAD solar 5.5kw |
260-480V |
200-900V |
480-650V |
|
451 |
4/6SSC35/4-A/D |
65m³/h-80m-530V-7500W |
35 |
10 |
4 |
AC/DC |
WAD solar 7.5kw |
260-480V |
200-900V |
480-650V |
|
452 |
4/6SSC32/4-A/D |
65m³/h-100m-530V-9200W |
32 |
12.5 |
4 |
AC/DC |
WAD solar 9.2kw |
260-480V |
200-900V |
480-650V |
|
453 |
4/6SSC32.5/4-A/D |
65m³/h-120m-530V-11000W |
32.5 |
15 |
4 |
AC/DC |
WAD solar 11kw |
260-480V |
200-900V |
480-650V |
|
454 |
4/6SSC46/3-A/D |
95m³/h-65m-530V-7500W |
46 |
10 |
3 |
AC/DC |
WAD solar 7.5kw |
260-480V |
200-900V |
480-650V |
|
455 |
4/6SSC45.5/3-A/D |
95m³/h-85m-530V-11000W |
46 |
15 |
3 |
AC/DC |
WAD solar 11kw |
260-480V |
200-900V |
480-650V |
Characteristic Curves


4/6SSC-AC/DC Dimenision
![]() |
No. |
WASSERMANN CODE |
Discharge(In) |
A |
B |
C |
D |
||||
|
in |
mm |
in |
mm |
in |
mm |
in |
mm |
||||
|
431 |
4/6SSC17/1-A/D |
3" |
11 |
278 |
10 |
258 |
21 |
536 |
5.7 |
145 |
|
|
432 |
4/6SSC17/2-A/D |
3" |
13 |
324 |
10 |
258 |
23 |
582 |
5.7 |
145 |
|
|
433 |
4/6SSC17/3-A/D |
3" |
15 |
370 |
11 |
278 |
26 |
648 |
5.7 |
145 |
|
|
434 |
4/6SSC17/4-A/D |
3" |
16 |
416 |
12 |
298 |
28 |
714 |
5.7 |
145 |
|
|
435 |
4/6SSC30/2-A/D |
3" |
17 |
422 |
11 |
278 |
28 |
700 |
5.7 |
145 |
|
|
436 |
4/6SSC30/3-A/D |
3" |
20 |
517 |
12 |
298 |
32 |
815 |
5.7 |
145 |
|
|
437 |
4/6SSC15/5-A/D |
3" |
16.4 |
416 |
12 |
298 |
28.1 |
714 |
3.9/5.7 |
100/145 |
|
|
438 |
4/6SSC18/5-A/D |
3" |
18 |
462 |
13 |
318 |
31 |
780 |
5.7 |
145 |
|
|
439 |
4/6SSC18/6-A/D |
3" |
20 |
508 |
13 |
338 |
33 |
846 |
5.7 |
145 |
|
|
440 |
4/6SSC18/7-A/D |
3" |
22 |
554 |
16 |
398 |
37 |
952 |
5.7 |
145 |
|
|
441 |
4/6SSC17/7-A/D |
3" |
16.4 |
416 |
12 |
298 |
28.1 |
714 |
3.9/5.7 |
100/145 |
|
|
442 |
4/6SSC18.5/7-A/D |
3" |
22 |
554 |
16 |
398 |
37.5 |
952 |
3.9/5.7 |
100/145 |
|
|
443 |
4/6SSC31/4-A/D |
3" |
20 |
517 |
12 |
298 |
32.1 |
815 |
3.9/5.7 |
100/145 |
|
|
444 |
4/6SSC30/4-A/D |
3" |
24 |
612 |
13 |
318 |
37 |
930 |
5.7 |
145 |
|
|
445 |
4/6SSC30/5-A/D |
3" |
28 |
707 |
13 |
338 |
41 |
1045 |
5.7 |
145 |
|
|
446 |
4/6SSC30/6-A/D |
3" |
32 |
802 |
16 |
398 |
47 |
1200 |
5.7 |
145 |
|
|
447 |
4/6SSC30.1/6-A/D |
3" |
32 |
802 |
16 |
398 |
47.2 |
1200 |
3.9/5.7 |
100/145 |
|
|
448 |
4/6SSC30.2/6-A/D |
3" |
32 |
802 |
16 |
398 |
47.2 |
1200 |
3.9/5.7 |
100/145 |
|
|
449 |
4/6SSC35/2-A/D |
3" |
17 |
422 |
13 |
318 |
29 |
740 |
5.7 |
145 |
|
|
450 |
4/6SSC35/3-A/D |
3" |
20 |
517 |
13 |
338 |
34 |
855 |
5.7 |
145 |
|
|
451 |
4/6SSC35/4-A/D |
3" |
24 |
612 |
16 |
398 |
40 |
1010 |
5.7 |
145 |
|
|
452 |
4/6SSC32/4-A/D |
3" |
22 |
568 |
16 |
398 |
38 |
966 |
3.9/5.7 |
100/145 |
|
|
453 |
4/6SSC32.5/4-A/D |
3" |
22 |
568 |
16 |
398 |
38 |
966 |
3.9/5.7 |
100/145 |
|
|
454 |
4/6SSC46/3-A/D |
4" |
22 |
568 |
16 |
398 |
38 |
966 |
5.7 |
145 |
|
|
455 |
4/6SSC45.5/3-A/D |
3" |
22 |
568 |
16 |
398 |
38 |
966 |
3.9/5.7 |
100/145 |
|
Free Accessories

Packaging

Features
- Proven motor and pump technology ensures long-term reliability.
- Maximum Power Point Tracking (MPPT) optimizes input power efficiency.
- Soft-start function prevents water hammer and extends system lifespan.
- Brushless magnet motor enables easy installation and reduced maintenance.
- CE certified for safety and compliance.
Advantage
- Dual-mode drive ensures uninterrupted power supply.
The system automatically identifies and switches between AC grid power and DC solar/battery power, enabling energy complementarity. Solar power is prioritized when sunlight is abundant; during cloudy or rainy weather or at night, it automatically switches to grid power or backup power, completely solving the problem of water supply interruption in pure solar-powered pumps during prolonged cloudy periods.
- High efficiency, intelligence, and energy saving
The built-in intelligent controller features MPPT and voltage adaptive functions, maximizing solar energy utilization and achieving soft start and power optimization in AC mode, resulting in an overall energy saving of 30%-50%.
Application Scenarios




IT'S A PLEASURE TO COOPERATE WITH YOU
- Stock
- After sales support
- Fast delivery:15-30 days
- Clear installation instruction
- No MOQ
- Logistics support
- 18 months warranty
- Customization, OEM/ODM available
- Fast response
- Qualified sales manager
- Flexible payment terms
- 24/7 technical support
- Sample available

FAQ
Routine maintenance of AC/DC solar submersible pumps
1. Energy System Maintenance: Regularly clean dust, snow, or debris from the surface of the solar panels to ensure efficient energy conversion. Check that the AC/DC line connections are secure to prevent oxidation or loosening.
2. Equipment Operation Monitoring: Observe the controller indicator lights or display screen to confirm that the power supply mode switches normally and there are no alarm messages. Note any unusual noises from the water pump during operation and record them regularly.
3. Specific Environmental Protection: Keep the controller enclosure dry and well-ventilated, avoiding direct sunlight or rain. In cold regions, drain the water from the pipes when not in use; in sandy environments, check if the water inlet filter is clogged, etc.